Kranti / AEW / Electromagnetic flow meters
KPE-100
Electromagnetic family with differing document scopes
Obtain an exact model, size, liner, electrode, power and output configuration. The general catalogue, dated price list and project sheet must not be merged.
MODEL OVERVIEW
What the KPE-100 offers
- Obtain an exact model, size, liner, electrode, power and output configuration. The general catalogue, dated price list and project sheet must not be merged.
Manufacturer’s documented description: AEW/136, 11 August 2026, pp. 11. Options and qualifications above are retained as stated.
Check these document differences
Diameter scope
General electromagnetic catalogue, undated, p.2: 15–3000 mm
AEW/136, 11 August 2026, p.11: price tables to 1200 mm; project KPE-100 sheet, undated, p.1: 25–300 mm
Request written confirmation for the offered size and configuration before using either value.
Configuration limits
General catalogue pp.2–3: 0.2–12 m/s; rubber 85°C / PTFE 150°C
Project KPE-100 sheet pp.1–2: 0.5–10 m/s; EPDM plus 120°C; confirm this combination
Request written confirmation for the offered size and configuration before using either value.
Table integrity
General catalogue p.2 has visibly shifted conductivity/repeatability labels
General catalogue p.3 flow table does not fully reconcile with stated velocity envelope; request calibrated span
Request written confirmation for the offered size and configuration before using either value.
TECHNICAL DATA
KPE-100 specifications
| Parameter | Documented value |
|---|---|
| Measuring principle | electromagneticAEW/136, 11 August 2026, 11 |
| Fluid temperature | PTFE: 150°C; hard rubber: 85°C in this scheduleS34 · 11 |
| Wetted materials | SS316 standard electrode; PTFE or hard-rubber liner. Other electrodes on request.S34 · 11 |
| Connections | ASA150 through DN250; PN10 from DN300. PN16/PN25/ASA300 on request.S34 · 11 |
| Transmitter protection | Die-cast enclosure IP67S34 · 11 |
| Power supply | 230 VAC / 24 VDC / battery variants; choose oneS34 · 11 |
| Battery life and assumptions | Optional battery version claims 3 years; operating assumptions not suppliedS34 · 11 |
| Included outputs | 4–20 mA and RS485 stated standard in AEW/136S34 · 11 |
| Optional outputs | HART; telemetry; remote display with up to 5 m cableS34 · 11 |
| Body material | SS304 measuring tube; aluminium die-cast enclosureS34 · 11 |
| Electrode options | Hastelloy C / platinum / titanium / tantalum on requestS34 · 11 |
| Display | Graphic display; 16 × 2 line display wordingS34 · 11 |
Kranti electromagnetic brochure: published dimensions and flow
S38 p.3
Values preserved as printed. Flow endpoints do not consistently match the brochure velocity statement; do not use this table as a validated sizing schedule.
| DN (mm) | OD (mm) | W (mm) | H (mm) | Face-to-face (mm) | Minimum (m³/h) | Maximum (m³/h) |
|---|---|---|---|---|---|---|
| 15 | 88.9 | 66 | 90 | 200 | 0.03 | 6.4 |
| 20 | 98.4 | 66 | 98 | 200 | 0.11 | 11 |
| 25 | 107.9 | 66 | 108 | 200 | 0.18 | 18 |
| 32 | 117.5 | 69 | 118 | 200 | 0.29 | 29 |
| 40 | 127 | 79 | 127 | 200 | 0.45 | 45 |
| 50 | 152.4 | 79 | 152 | 200 | 0.71 | 71 |
| 65 | 177.8 | 79 | 178 | 200 | 1.19 | 119 |
| 80 | 190.5 | 79 | 191 | 200 | 1.81 | 181 |
| 100 | 228.6 | 108 | 229 | 250 | 2.83 | 283 |
| 125 | 254 | 106 | 254 | 250 | 4.42 | 442 |
| 150 | 279.4 | 155 | 280 | 300 | 6.36 | 636 |
| 200 | 342.9 | 171 | 343 | 350 | 11.3 | 1130 |
| 250 | 406.4 | 203 | 407 | 450 | 17.66 | 1766 |
| 300 | 450 | 240 | 483 | 500 | 25.43 | 2543 |
| 350 | 510 | 298 | 533 | 550 | 34.62 | 3462 |
| 400 | 570 | 336 | 597 | 600 | 45.22 | 4522 |
| 450 | 620 | 398 | 635 | 698 | 57.23 | 5723 |
| 500 | 675 | 450 | 700 | 768 | 70.65 | 7065 |
| 600 | 785 | 550 | 813 | 918 | 101.74 | 10174 |
Details to confirm for the offered configuration
These parameters are not established as exact-model values in this record. Some may not apply to this technology.
- Q1 m3 h
- Q2 m3 h
- Q3 m3 h
- Q4 m3 h
- Working pressure and temperature
- Approvals and scope
DUTY & SELECTION
Where to consider this type
An electromagnetic meter, often called a mag meter or EMF meter, measures flow using the electrical signal induced when a conductive liquid moves through a magnetic field.
Installation and commissioning
Before the meter is selected
- Lowest measured conductivity
- Liner, electrode and seal compatibility
- Full measuring tube, grounding and pipe profile
- Integral/remote configuration, accuracy basis and simultaneous powered outputs
Before the system is handed over
- Confirm the installation drawing, orientation and access for service.
- Match the actual flow range and permitted pressure loss to the project.
- Record meter serial number, start reading and any output scaling.
- Commission communications against the receiving system and retain the test record.
Reading and communication
No electronic output is established for the base record. Confirm a compatible pickup or communication variant if remote reading is required; do not assume another model’s output can be fitted.
Understand pulse, wired and wireless reading ↗Documents and purchase checks
Read the Kranti / AEW technical reference → · Browse the source index
Source: AEW/136, 11 August 2026, pp. 11. Reviewed 2026-09-09.
Ask for these before ordering
- Approved drawing for the exact model, size and configuration
- Serial-number calibration or factory test record
- Applicable approval certificate and exact scope
- Installation manual and required straight pipe
- Protocol/register map and output power requirements
- Option/accessory codes with included components
- Pressure-loss curve, flange drilling and face-to-face length
- Current written commercial and warranty terms
SPECIFY YOUR REQUIREMENT
Get a quotation for KPE-100
Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.
Compare related models
Similar technology does not mean equivalent performance. Compare exact configurations.