Kranti / AEW / Woltman bulk water meters
KFLOW WP-SDC
Separate KFLOW make in the AEW list; Woltman 50–300 mm
CI FG260, Class B, R80, copper-can register, IP68, 16 bar, 50°C, flanged. Includes 125 mm. The document claims MID marking
MODEL OVERVIEW
What the KFLOW WP-SDC offers
- CI FG260, Class B, R80, copper-can register, IP68, 16 bar, 50°C, flanged. Includes 125 mm. The document claims MID marking
- exact certificate not verified.
Manufacturer’s documented description: AEW/136, 11 August 2026, pp. 10. Options and qualifications above are retained as stated.
TECHNICAL DATA
KFLOW WP-SDC specifications
| Parameter | Documented value |
|---|---|
| Measuring principle | woltmanAEW/136, 11 August 2026, 10 |
| Nominal diameter (DN) | 50, 65, 80, 100, 125, 150, 200, 250, 300S34 · 10 |
| R ratio | R80S34 · 10 |
| Accuracy statement | ±2% at Qt/Qn/Qmax; ±5% at QminS34 · 10 |
| Fluid temperature | Maximum 50°CS34 · 10 |
| Working pressure and temperature | Maximum 16 barS34 · 10 |
| Connections | Flanged endsS34 · 10 |
| Sensor protection | IP68 as statedS34 · 10 |
| Approvals and scope | MID marking claimed; 2004/22/EC and ISO 4064:2005 cited. Certificate scope not independently verified.S34 · 10 |
| Documented size scope | 50-300 mmAEW/136, 11 August 2026, 10 |
| Body material | Cast iron FG260S34 · 10 |
| Register options | Copper-can register; anti-magnetic protectionS34 · 10 |
Details to confirm for the offered configuration
These parameters are not established as exact-model values in this record. Some may not apply to this technology.
- Q1 m3 h
- Q2 m3 h
- Q3 m3 h
- Q4 m3 h
DUTY & SELECTION
Where to consider this type
Water drives a helical rotor used for larger flows. Many ranges have flanged bodies and removable measuring inserts.
Installation and commissioning
Before the meter is selected
- Overnight flow and continuous/short peak demand
- Rotor-axis and pipe orientation requirements
- Removable insert service clearance
- Flange drilling, head loss and straight pipe
Before the system is handed over
- Confirm the installation drawing, orientation and access for service.
- Match the actual flow range and permitted pressure loss to the project.
- Record meter serial number, start reading and any output scaling.
- Commission communications against the receiving system and retain the test record.
Reading and communication
No electronic output is established for the base record. Confirm a compatible pickup or communication variant if remote reading is required; do not assume another model’s output can be fitted.
Understand pulse, wired and wireless reading ↗Documents and purchase checks
Read the Kranti / AEW technical reference → · Browse the source index
Source: AEW/136, 11 August 2026, pp. 10. Reviewed 2026-09-09.
Ask for these before ordering
- Approved drawing for the exact model, size and configuration
- Serial-number calibration or factory test record
- Applicable approval certificate and exact scope
- Installation manual and required straight pipe
- Protocol/register map and output power requirements
- Option/accessory codes with included components
- Pressure-loss curve, flange drilling and face-to-face length
- Current written commercial and warranty terms
SPECIFY YOUR REQUIREMENT
Get a quotation for KFLOW WP-SDC
Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.
Compare related models
Similar technology does not mean equivalent performance. Compare exact configurations.