  "id": "lehry/liv-emf-cs-rtfe-002",
  "slug": "liv-emf-cs-rtfe-002",
  "brand": "lehry",
  "model_code": "LIV-EMF-CS-RTFE-002",
  "title": "LIV-EMF-CS-RTFE-002",
  "technology": "electromagnetic",
  "description": "Electromagnetic — Integral, 25-bar list",
  "notes": "CS flange/housing, PTFE lining, SS316L electrodes; ±0.5 FSD as printed; 4–20 mA/pulse/RS485. HART inclusion varies by document; confirm exact configuration.",
  "facts": {
    "model": {
      "value": "LIV-EMF-CS-RTFE-002",
      "status": "manufacturer_claim",
      "source": {
        "document": "Lehry DLP",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "47–48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
      }
    },
    "manufacturer": {
      "value": "Lehry",
      "status": "manufacturer_claim",
      "source": {
        "document": "Lehry DLP",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "47–48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
      }
    },
    "configuration_code": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "measuring_principle": {
      "value": "electromagnetic",
      "status": "editorial_guidance",
      "source": {
        "document": "Lehry DLP",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "47–48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
      }
    },
    "installation_style": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "fluid_compatibility": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "conductivity_min_uS_cm": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "solids_limits": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "dn_mm": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "actual_internal_diameter_mm": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "q1_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "q2_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "q3_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "q4_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "r_ratio": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "legacy_flow_ratings_with_standard": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "flow_min_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "flow_max_continuous_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "flow_peak_m3_h": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "peak_duration_limit": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "accuracy_expression": {
      "value": "±0.5 FSD as printed; confirm percent notation and calibrated full scale",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "accuracy_basis": {
      "value": "Full-scale basis in list; differs from other sheet wording",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "accuracy_conditions": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "orientation": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "temperature_fluid_C": {
      "value": "0–70°C standard; 180°C on request in list. Other technical-sheet limits differ.",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "temperature_ambient_C": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "working_pressure_bar_at_temperature": {
      "value": "25 bar maximum; temperature-dependent limits require confirmation",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "pressure_loss_curve": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "wetted_materials": {
      "value": "PTFE liner; SS316L electrode",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "connection_standard_and_size": {
      "value": "ANSI B16.5 Class 300",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "face_to_face_mm": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "straight_runs_and_conditions": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "sensor_ip_and_immersion_conditions": {
      "value": "IP67 integral / IP68 remote list wording; verify sensor and transmitter separately",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "transmitter_ip": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "power_configuration": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "battery_life_and_assumptions": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "included_outputs": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "optional_outputs": {
      "value": "4–20 mA / pulse / RS485; HART extra in list note, despite interface list wording",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    },
    "protocol_and_map": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "pulse_litres_per_pulse": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "measurement_log_transmit_intervals": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "offline_storage_and_backfill": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "approvals_exact_scope": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "included_accessories": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "recurring_costs": {
      "value": null,
      "status": "unknown",
      "source": null
    },
    "documented_description": {
      "value": "Electromagnetic — Integral, 25-bar list",
      "status": "manufacturer_claim",
      "source": {
        "document": "Lehry DLP",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "47–48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
      }
    },
    "documented_features": {
      "value": "CS flange/housing, PTFE lining, SS316L electrodes; ±0.5 FSD as printed; 4–20 mA/pulse/RS485. HART inclusion varies by document; confirm exact configuration.",
      "status": "manufacturer_claim",
      "source": {
        "document": "Lehry DLP",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "47–48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
      }
    },
    "body_material": {
      "value": "Carbon steel ASTM A216 enclosure and flange",
      "status": "manufacturer_claim",
      "source": {
        "document": "S5: Lehry Master Price List (DLP) - 0825.pdf",
        "document_date_or_revision": "25 August 2025",
        "page_or_section": "48",
        "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; this document scope only"
      }
    }
  },
  "source": {
    "document": "Lehry DLP",
    "document_date_or_revision": "25 August 2025",
    "page_or_section": "47–48",
    "exact_model_and_configuration": "LIV-EMF-CS-RTFE-002; documented family, size/options require confirmation"
  },
  "size_values": [
    25
  ],
  "connections": [
    "flanged"
  ],
  "outputs": [
    "pulse",
    "4-20ma",
    "rs485"
  ],
  "power": [],
  "services": [
    "water"
  ],
  "conflicts": [
    [
      "Flow span and configuration",
      "Lehry remote EMF sheet, undated, p.4: DN100 8.4–140 m³/h",
      "Lehry integral sheet p.3 and DLP 25 August 2025 p.47: DN100 8.4–339 m³/h. These scopes differ; request the offered configuration"
    ],
    [
      "Specification blocks",
      "Lehry technical sheets contain differing size, temperature, IP and accuracy-basis blocks",
      "Do not combine options across sheets. DLP pp.47–48 also distinguishes 16-bar and 25-bar configurations"
    ]
  ],
  "price_band": null,
  "last_reviewed": "2026-09-09",
  "facet_note": "Discovery tags come from the documented description, including optional capabilities. Confirm inclusion and exact size/configuration."
}